What Is NFPA 96?

NFPA 96 is the National Fire Protection Association Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations. It sets the mandatory fire-safety rules for restaurant hood exhaust systems, grease ductwork, fans, air control, fire prevention, and cleaning frequency. All Maryland restaurants must follow NFPA 96 to pass Fire Marshal inspections, Health Department inspections, and insurance compliance checks.

NFPA 96

Compliant

24/7

Emergency

MD

Statewide

Quick Navigation

Exhaust System Cleaning

Cleaning Frequency Table

Hood System Requirements

Ventilation Requirements

Grease Filter Requirements

Fire Marshal Inspector Requirements

Maryland Frequency

Exhaust System Cleaning

11.6.2 Installation Requirements:

11.6.2.1 Installation systems shall be performed only by persons properly trained and qualified to install the specific system being provided
11.6.2.2 The installer shall provide certification to the authority having jurisdiction that the installation is in agreement with the terms of the listing and the manufacturers instructions and/ or improve design

01

02

03

04

05

06

07

08

09

Required Cleaning Frequency

NFPA 96 sets minimum cleaning frequency based on cooking operations:

Cleaning Frequency

Cooking Operation Type

Typical Businesses / Fire Risk

Monthly

Solid-fuel (wood/charcoal), heavy grease, fried chicken, hibachi

Low-volume operations — Modern cooking. High-volume cooking (wings, takeout, diners, fast food)

Typical Businesses: wood-fired pizza, charcoal grill, Brazilian steakhouse, BBQ smokehouse, high-temp wok, tandoor.

Fire Risk: Highest grease loading, rapid duct buildup, strong Fire Marshal scrutiny.

Quarterly

High volume cooking — 24 hour, trial, boiling and wok operation

Typical Businesses: casual dine-in restaurants, hotel kitchens, mid-volume restaurants.

Fire Risk: Moderate grease load, must still show bare-metal cleaning in ducts.

Semi Annual

Low-volume operations — Modern cooking. High-volume cooking (wings, takeout, diners, fast food)

Typical Businesses: fried chicken chains, wings, diners open late, busy takeout kitchens, franchise burger/fast-food.

Fire Risk: Heavy daily use, continuous fryers, frequent inspections.

Semi Annual

Low volume cooking (churches, daycares). Non-grease cooking (churches, daycares)

Typical Businesses: churches, daycares, community centers with limited cooking.

Fire Risk: Minimal grease, but NFPA 96 still requires documented cleaning.

IMPORTANT: These frequencies are NFPA 96 minimums. Local Maryland Fire Marshals can require more frequent cleaning based on inspections. HydroForce Power Washing LLC helps set the right schedule for each specific kitchen.

Hood System Requirements

NFPA 96 mandates specific requirements for commercial kitchen exhaust hood systems:
REQ.01

Exhaust ducts must be constructed of continuous welded steel, minimum of 16-gauge (carbon steel) or 18-gauge (stainless steel), and installed with liquid-tight seams.

REQ.02

All seams must be liquid tight

REQ.03
Hood interior must be accessible for cleaning and inspection
REQ.04
Grease containment system must be properly installed and maintained
REQ.05
Drip trays must be present and functional
REQ.06

Access panels must be installed for proper ductwork inspection

REQ.07
Hood must extend beyond cooking equipment by minimum 6 inches on all sides
REQ.08
All surfaces must be cleaned during service

Ventilation Requirements

Proper ventilation is critical for fire safety and NFPA 96 compliance:
NEG. PRESSURE
-0.05 in.wc
AIRFLOW · CFM

01

Exhaust fan must pull sufficient CFM to remove grease vapor effectively

02

Ductwork must be welded construction and fire-rated per NFPA 96 standards

03

No air leaks allowed at seams, joints, or connections

04

Rooftop exhaust fan must have a hinge kit installed for maintenance access

05

Grease must not pool on roof surfaces or around fan housing

06

Fan blades must be cleaned during each service

07

Fan housing and fan bowl must be free of grease accumulation

08

Ventilation system must maintain negative pressure in hood

09

Make-up air system must be properly balanced with exhaust

Grease Filter Requirements

✓ Approved

UL 1046 and NFPA 96

Baffle Filter

✓ Approved

UL 1046 & NFPA 96

spark arrestor filter

✕ Not Allowed
Mesh Filter
Fire hazard · Non-compliant

Fire Marshal Inspector Requirements

NFPA 96 compliant cleaning services must provide proper documentation for Fire Marshal inspections:
CERT.NO 2025-0847
Certificate of

Compliance

Facility
Restaurant Kitchen
Service Date
Documented
Technician
Certified ✓
Next Service
Scheduled
Approved

HYDROFORCE

Trust & Compliance

Built for Fire Code. Trusted by Operators.

NFPA 96 Compliant

Certified

Fire Marshal Approved Cleaning

Certified

Fully Insured

Certified

Commercial Kitchen Specialists

Certified

Before & After Documentation

Certified

Emergency Service Available

Certified

Our Services

Commercial Appliance Cleaning Services

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Kitchen Exhaust Hood Cleaning

Full hood, plenum and interior cleaned to bare metal.

Before & After

Cleaned to Bare Metal. Documented.

Hood Interior

NFPA 96 ✓

APPLIANCE CLEANING

NFPA 96 ✓

ROOFTOP FAN

NFPA 96 ✓

Stay NFPA 96 Compliant & Pass Inspection

Certified Maryland commercial kitchen cleaning, documented to Fire Marshal standards.

NFPA 96 Compliance Statement: HydroForce Power Washing LLC performs commercial kitchen exhaust cleaning to NFPA 96 standards, providing full documentation, before/after photos, and compliance certificates for Maryland Fire Marshal inspections.

Contact

Business Hours

© 2026 HydroForce Power Washing LLC. All rights reserved.